{"product_id":"axis-d8208-r-managed-industrial-switch-with-90w-poe","title":"Axis D8208-R Managed Industrial Switch with 90W PoE++","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eDescription\u003c\/li\u003e\n\u003cli\u003eSpecifications\u003c\/li\u003e\n\u003cli\u003eDownloads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch2 style=\"text-align: center;\"\u003eManaged Industrial Switch for High-Power Surveillance Networks\u003c\/h2\u003e\n\u003cp style=\"text-align: center;\"\u003eThis 8-port managed industrial PoE++ Gigabit switch includes two SFP+ data ports allowing you to connect extra devices depending on your needs.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0581\/5556\/5242\/files\/02621-001_2.webp?v=1780482991\"\u003e\u003cbr\u003eFor demanding installations\u003c\/strong\u003e\u003cbr\u003eThis ruggedized industrial switch is developed for challenging environments when mounted inside a surveillance cabinet. Designed to withstand shock and vibrations, it can handle temperatures from -40 °C to 60 °C (-40 °F to 140 °F). This makes it ideal for demanding installations such as alongside highways and tunnels, and in industrial and outdoor environments like railways and harbors.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0581\/5556\/5242\/files\/02621-001_1.webp?v=1780482991\"\u003e\u003cbr\u003eFlexible installations\u003c\/strong\u003e\u003cbr\u003eThis rugged 8-port switch can deliver up to 90 W PoE++ (IEEE 802.3bt) per port, with a total power budget of 480 W. In addition, two SFP+ ports with 10 Gbit SFP+ uplink allows for long-distance installations.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eEasy to install and configure\u003c\/strong\u003e\u003cbr\u003eAXIS D8208-R ensures easy configuration with Axis products. The unique web graphic user interface offers a graphic topology for easy overview of all devices in the system. Plus, it provides information, status, and notifications about connected devices. This allows you to manage all connected devices, reboot cameras in the system, monitor network traffic and cable diagnostics, and much more.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ctable style=\"font-family: Arial; font-size: 14px; border-collapse: collapse; width: 100%; table-layout: fixed;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"width: 25%; padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003eSecurity\u003c\/td\u003e\n      \u003ctd style=\"width: 25%; padding: 10px; border: 1px solid #ddd;\"\u003eAccess Control List, Port Security, IP Source Guard, Storm Control, Private VLAN, DHCP Snooping, ARP Inspection, HTTPS encryption, Password protection\u003c\/td\u003e\n      \u003ctd style=\"width: 25%; padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003eNetwork protocols\u003c\/td\u003e\n      \u003ctd style=\"width: 25%; padding: 10px; border: 1px solid #ddd;\"\u003eIPv4, IPv6, HTTP, HTTPS, SMTP, Bonjour, UPnP®, SNMP v1\/v2c\/v3, DNS, NTP, RTSP, TCP, UDP, IGMP, ICMP, DHCP, ARP, SSH, RADIUS, TACACS+, Syslog, IEEE 802.1X, IEEE 802.3X, IEEE 802.1p, 802.1Q (VLAN), LLDP, LLDP-Med, STP, MSTP, RSTP, LACP, RRPP\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003eThroughput\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e46.130 Mpps\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003eSwitching capacity\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e62 Gbps\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003eMAC table\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e16 K\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003eJumbo frames\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e10240 Bytes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003eEMC\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eEN 55035, EN 55032 Class A, EN 50121-4, EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, Australia\/New Zealand: RCM AS\/NZS CISPR 32 Class A, Canada: ICES(A)\/NMB(A), Japan: VCCI Class A, USA: FCC Part 15 Subpart B Class A, Railway: IEC 62236-4\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003eSafety\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eIEC\/EN\/UL 62368-1 ed. 3\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003eEnvironment\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eIEC 60068-2-6, IEC 60068-2-27, NEMA TS 2 (2.2.7-2.2.9), 60068-2-31 (Free fall - Procedure 1), IEC\/EN 60529 IP30\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003eCasing\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eAluminum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003eColor\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eBlack\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003ePower\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eRequired 44 ~ 57 V DC input for IEEE 802.3af, Type 1 Class 3, max 15.4 W output\u003cbr\u003eRequired 50 ~ 57 V DC input for IEEE802.3at, Type 2 Class 4, max 30 W output\u003cbr\u003eRequired 50 ~ 57 V DC input for IEEE802.3bt, Type 3 Class 6, max 60 W output\u003cbr\u003eRequired 52 ~ 57 V DC input for IEEE802.3bt, Type 4 Class 8, max 90 W output\u003cbr\u003eMax 11.2 A at 480 W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003ePin assignment\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003ePower over pairs: 3\/6, 4\/5 (+ve) and 1\/2, 7\/8 (-ve)\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003ePoE output\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eUp to 90 W per port\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003ePoE Power budget\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e480 W\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003ePoE ports\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eRJ45 10BASE-T\/100BASE-TX\/1000BASE-T (6x)\u003cbr\u003eRJ45 100BASE-TX\/1000BASE-T\/2.5GBASE-T (2x)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003eData ports\/Uplink\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e10GBASE-LR\/SR SFP+ (2x)\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003ePower connectors\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003ePower connector port (2x for power redundancy)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003eConsole\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eRJ45 (1x)\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003eSurge protection\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eDC Power: 1 kV CM, 0.5 kV DM\u003cbr\u003e6kV on all network ports\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003eOperating conditions\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e-40 to 60 °C (-40 °F to 140 °F)\u003cbr\u003eMaximum temperature according to NEMA TS 2 (2.2.7): 74 °C (165 °F)\u003cbr\u003eHumidity 5–95% RH (non-condensing)\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003eStorage conditions\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e-40 °C to 85 °C (-40 °F to 185 °F)\u003cbr\u003eHumidity 5–95% RH (non-condensing)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003eDimensions\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eWidth: 62 mm (2.44 in)\u003cbr\u003eHeight: 168 mm (6.61 in)\u003cbr\u003eDepth: 130 mm (5.11 in)\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e892 g (1.967 lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003eIncluded accessories\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eInstallation guide, mounting bracket for din rail, DB-9 console cable, two mounting brackets for AXIS TQ1808-VE Surveillance Cabinet\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003eOptional accessories\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eAXIS TQ1808-VE Surveillance Cabinet\u003cbr\u003ePower Supply DIN PS56 480 W\u003cbr\u003eAXIS TD8901 SFP+ Module LC.LR.X\u003cbr\u003eAXIS TD8902 SFP+ Module LC.SR.X\u003cbr\u003eFor more accessories, see axis.com\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003eManagement software\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eAXIS Device Manager\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003eWarranty\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e5-year warranty\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-family: Arial, sans-serif; font-size: 14px; height: 94.5px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: rgb(242, 242, 242); font-weight: bold; height: 33.9722px;\"\u003e\n\u003cth style=\"border: 1px solid rgb(221, 221, 221); padding: 10px; height: 33.9722px;\"\u003eDescription\u003c\/th\u003e\n\u003cth style=\"border: 1px solid rgb(221, 221, 221); padding: 10px; text-align: center; height: 33.9722px;\"\u003eDownloads\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 60.5278px;\"\u003e\n\u003ctd style=\"background-color: rgb(249, 249, 249); border: 1px solid rgb(221, 221, 221); padding: 10px; height: 60.5278px;\"\u003eDatasheet\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid rgb(221, 221, 221); padding: 10px; text-align: center; height: 60.5278px;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0581\/5556\/5242\/files\/datasheet-axis-d8208-r-industrial-poe_-switch-en-US-531193.pdf?v=1780483015\" title=\"Datasheet\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Axis","offers":[{"title":"Default Title","offer_id":45944053137594,"sku":"02621-001","price":1151.04,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0581\/5556\/5242\/files\/02621-001_1.png?v=1780483119","url":"https:\/\/screenmoove.com\/products\/axis-d8208-r-managed-industrial-switch-with-90w-poe","provider":"Screen Moove","version":"1.0","type":"link"}