{"product_id":"planet-gs-4210-8up2x-8-port-10-100-1000t-802-3bt-poe-2-port-10g-sfp-managed-ethernet-switch","title":"Planet GS-4210-8UP2X 8-Port 10\/100\/1000T 802.3bt PoE + 2-Port 10G SFP+ Managed Ethernet Switch","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eDescription\u003c\/li\u003e\n\u003cli\u003eSpecifications\u003c\/li\u003e\n\u003cli\u003eDownloads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch2 style=\"text-align: center;\"\u003eEnterprise 802.3bt PoE++ Networking\u003c\/h2\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003ePerfect Managed PoE++ Switch with Advanced L2+ Switching and Security\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003ePLANET GS-4210-8UP2X Gigabit 802.3bt PoE++ Managed Switch features intelligent PoE functions to improve the availability of critical business applications. It provides IPv6\/IPv4 dual stack management and a built-in L2+ Gigabit switching engine. The GS-4210-8UP2X includes 8 10\/100\/1000BASE-T 802.3bt PoE++ ports and 2 10 Gigabit fiber ports, with a total power budget of 240 watts. It offers a quick, safe and cost-effective PoE++ network solution for small businesses and enterprises.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0581\/5556\/5242\/files\/edm2_GS-4210-8UP2X.png?v=1783425613\"\u003e\u003cbr\u003eCybersecurity Network Solution to Minimize Security Risks\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eThe cybersecurity features protect switch management in mission-critical networks. SSHv2 and TLSv1.3 provide strong protection against advanced threats.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0581\/5556\/5242\/files\/GS-4210-8UP2X-1.png?v=1783425613\"\u003e\u003cbr\u003eRedundant Ring, Fast Recovery for Critical Network Applications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eThe GS-4210-8UP2X supports ITU-T G.8032 ERPS and Spanning Tree Protocol to enhance reliability and uptime.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0581\/5556\/5242\/files\/Common_PoE-switch-ERPS_Redundant-Connection_221edd20-2a56-4651-a2f9-50810efda345.png?v=1783425613\"\u003e\u003cbr\u003e802.3bt PoE++ 95-Watt Power over 4-Pair UTP Solution\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eThe GS-4210-8UP2X supports IEEE 802.3bt PoE++ and can deliver up to 95 watts per port over standard Cat5e\/6 cabling for high-power devices such as PTZ cameras, network devices, thin clients, POS systems, kiosks, digital signage displays and PoE lighting.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0581\/5556\/5242\/files\/POE-171A-95-2_L_7456a941-9314-4463-8a96-57c3324ab57b.png?v=1783425613\"\u003e\u003cbr\u003e802.3bt PoE++ and Advanced PoE Power Output Mode Management\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eThe GS-4210-8UP2X supports 95W 802.3bt Type-4 PoE++ mode and 4-pair legacy mode for non-standard PoE devices. It also supports 36W end-span 802.3at PoE+ output mode.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eBuilt-in Unique PoE Functions for Powered Devices Management\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eThe GS-4210-8UP2X includes PD Alive Check, Scheduled Power Recycling, PoE Schedule, PoE Usage Monitoring and PoE Extension.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eIntelligent Powered Device Alive Check\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eThe switch can monitor connected powered devices in real time via ping. If a device stops responding, the switch can restart PoE power on that port to bring the device back online.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0581\/5556\/5242\/files\/Common_PD-Alive-Check_df4e39aa-22cf-457b-a421-ccccf14caa8a.png?v=1783425612\"\u003e\u003cbr\u003eScheduled Power Recycling\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eConnected PoE IP cameras or wireless access points can be rebooted at a scheduled time each week to reduce crashes caused by buffer overflow.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0581\/5556\/5242\/files\/Common_Scheduled-Power-Recycling_acb7b1c7-0f3f-4b9c-9cf6-2f39d1e41fdd.png?v=1783425612\"\u003e\u003cbr\u003ePoE Schedule for Energy Savings\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003ePoE scheduling allows power feeding to be enabled or disabled during specified time intervals, helping reduce energy use and improve security during non-business hours.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0581\/5556\/5242\/files\/Common_PoE-Schedule-for-Energy-Saving_5b671d48-6442-43ca-9625-d3ab4e92f527.png?v=1783425612\"\u003e\u003cbr\u003ePoE Usage Monitoring\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eThe web management interface allows administrators to monitor power usage of connected powered devices in real time.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e802.3at PoE+ Power and Ethernet Data Transmission Distance Extension\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eIn Extend mode, the switch supports 10Mbps duplex operation with up to 50W PoE output over distances up to 250 meters.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0581\/5556\/5242\/files\/Common_PoE-switch_Extend-Mode_4b660ce0-b001-4edc-b039-0470cd8ff466.png?v=1783425612\"\u003e\u003cbr\u003eEnvironment-Friendly Smart Fan Design for Silent Operation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eThe GS-4210-8UP2X features a rack-mount metal housing, low-noise design and smart fan technology to control fan speed automatically.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eIPv6\/IPv4 Dual Stack Management\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eThe switch supports both IPv6 and IPv4 protocols for flexible network deployment.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0581\/5556\/5242\/files\/Common_IPv6_IPv4-Dual-Stack-Management_175c2898-8e2d-435f-8d11-d57e4eb7c93e.png?v=1783425613\"\u003e\u003cbr\u003eRobust Layer 2 Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eThe GS-4210-8UP2X supports dynamic link aggregation, 802.1Q VLAN, Q-in-Q VLAN, MSTP, loop and BPDU guard, IGMP snooping, MLD snooping and LLDP.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0581\/5556\/5242\/files\/Common_Robust-Layer-2-Features_62c2837e-6ee7-442f-804f-afb07b3a31bb.png?v=1783425612\" alt=\"\"\u003e\u003cbr\u003eEfficient Traffic Control\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eQoS and traffic management features include storm control, per-port bandwidth control, IP DSCP QoS priority and remarking.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003ePowerful Security\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eThe switch supports Layer 2 to Layer 4 ACL, 802.1x authentication and private VLAN to enhance network security.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eAdvanced IP Network Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eDHCP Snooping, IP Source Guard and Dynamic ARP Inspection help prevent spoofing and invalid ARP traffic.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eEfficient Management\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eThe GS-4210-8UP2X supports command line, Web and SNMP management interfaces, plus Telnet and console access.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0581\/5556\/5242\/files\/Common_Secure-Management_6cc66e47-e251-4636-b100-fe0f4fa75204.png?v=1783425613\" alt=\"\"\u003e\u003cbr\u003eFlexibility and Long-Distance Extension Solution\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eThe switch supports Gigabit RJ45 copper interfaces and 100BASE-FX, 1000BASE-SX\/LX, 2.5G and 10G SFP fiber transceivers for long-distance uplinks.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eIntelligent SFP Diagnosis Mechanism\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eSFP-DDM allows administrators to monitor real-time SFP parameters, including optical power, temperature, laser bias current and transceiver voltage.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0581\/5556\/5242\/files\/Common_Intelligent-SFP_SFP_-Diagnosis-Mechanism_af2791e7-6141-4553-9308-72b36321d206.png?v=1783425613\" alt=\"\"\u003e\u003cbr\u003ePLANET CloudNMS – Cloud-Based Universal Network Management\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003ePLANET CloudNMS and mobile app allow IT staff to remotely manage network devices and powered devices in real time, with centralized monitoring, fault detection and instant alerts.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0581\/5556\/5242\/files\/CloudNMS-APP-5.png?v=1783425613\"\u003e\u003cbr\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003ePhysical Port:\u003c\/strong\u003e\u003cbr\u003e8 10\/100\/1000BASE-T ports with 95W 802.3bt PoE++ injector function\u003cbr\u003e2 10GBASE-SR\/LR SFP+ slots, backward compatible with 100\/1G\/2.5GBASE-X SFP transceivers\u003cbr\u003eRJ45 to DB9 console interface for switch management and setup\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eSwitching:\u003c\/strong\u003e\u003cbr\u003eHardware-based 10\/100Mbps half\/full duplex and 1000Mbps full duplex\u003cbr\u003eAuto-negotiation and auto MDI\/MDI-X\u003cbr\u003eIEEE 802.3x flow control\u003cbr\u003eBack pressure for half duplex operation\u003cbr\u003e16K MAC address table\u003cbr\u003e12K jumbo frame\u003cbr\u003eAutomatic address learning and aging\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003ePower over Ethernet:\u003c\/strong\u003e\u003cbr\u003eIEEE 802.3bt PoE++ compliant\u003cbr\u003e8 ports supporting up to 95 watts each\u003cbr\u003e240W total PoE power budget\u003cbr\u003eAutomatic PD detection\u003cbr\u003eCircuit protection\u003cbr\u003eRemote power feeding up to 100 meters in standard mode and 250 meters in extend mode\u003cbr\u003eTotal PoE power budget control\u003cbr\u003ePer-port PoE enable\/disable\u003cbr\u003ePoE priority and power limitation\u003cbr\u003ePD classification detection\u003cbr\u003ePD Alive Check\u003cbr\u003ePoE Schedule\u003cbr\u003eScheduled Power Recycling\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eLayer 2 Features:\u003c\/strong\u003e\u003cbr\u003eIEEE 802.1Q tagged VLAN\u003cbr\u003eQ-in-Q VLAN\u003cbr\u003eProtocol VLAN\u003cbr\u003ePrivate VLAN\u003cbr\u003eManagement VLAN\u003cbr\u003eGVRP\u003cbr\u003eSTP, RSTP and MSTP\u003cbr\u003eBPDU Guard, BPDU Filtering and BPDU Forwarding\u003cbr\u003eLACP\u003cbr\u003eStatic trunk\u003cbr\u003ePort mirror\u003cbr\u003eLoop protection\u003cbr\u003eERPS\u003cbr\u003eLLDP\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eQuality of Service:\u003c\/strong\u003e\u003cbr\u003eIngress and egress rate limit\u003cbr\u003eStorm control\u003cbr\u003eBroadcast, unknown unicast and unknown multicast control\u003cbr\u003eIEEE 802.1p CoS\u003cbr\u003eTOS, DSCP and IP precedence\u003cbr\u003eStrict Priority\u003cbr\u003eWRR\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eMulticast:\u003c\/strong\u003e\u003cbr\u003eIPv4 IGMP snooping v2\/v3\u003cbr\u003eIPv6 MLD snooping v1\/v2\u003cbr\u003eIGMP querier mode\u003cbr\u003eIGMP snooping port filtering\u003cbr\u003eMLD snooping port filtering\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eSecurity:\u003c\/strong\u003e\u003cbr\u003eRADIUS client\u003cbr\u003eRADIUS\/TACACS+ login authentication\u003cbr\u003eDHCP Option 82\u003cbr\u003eIPv4\/IPv6 IP-based ACL and ACE\u003cbr\u003eMAC-based ACL and ACE\u003cbr\u003eMAC security\u003cbr\u003eStatic MAC\u003cbr\u003eMAC filtering\u003cbr\u003ePort security\u003cbr\u003eDHCP Snooping\u003cbr\u003eDynamic ARP Inspection\u003cbr\u003eIP Source Guard\u003cbr\u003eDoS attack prevention\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eManagement:\u003c\/strong\u003e\u003cbr\u003eIPv4 and IPv6 dual stack management\u003cbr\u003eWeb management\u003cbr\u003eConsole and Telnet CLI\u003cbr\u003eSNMP v1\/v2c\/v3\u003cbr\u003eSSHv2 and TLSv1.3\u003cbr\u003eRMON\u003cbr\u003eSNMP trap\u003cbr\u003eUser privilege control\u003cbr\u003eTFTP client\u003cbr\u003eStatic and DHCP IP assignment\u003cbr\u003eFirmware upload\/download via HTTP\/TFTP\u003cbr\u003eConfiguration upload\/download via HTTP\/TFTP\u003cbr\u003eDual images\u003cbr\u003eHardware reset button\u003cbr\u003eSNTP\u003cbr\u003eSFP-DDM\u003cbr\u003eCable diagnostics\u003cbr\u003eICMPv4\/ICMPv6 remote ping\u003cbr\u003eLLDP and LLDP-MED\u003cbr\u003eRemote syslog\u003cbr\u003ePLANET Smart Discovery Utility\u003cbr\u003ePLANET NMS and CloudNMS\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; font-family:Arial, sans-serif; font-size:14px;\"\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003eCopper Ports\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e8 10\/100\/1000BASE-T RJ45 auto-MDI\/MDI-X ports\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003ePoE Injector Port\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e8 ports with 802.3bt PoE++ injector function (Ports 1 to 8)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003eSFP Ports\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e2 10GBASE-SR\/LR SFP+ interfaces (Port XG1 to Port XG2); backward compatible with 100\/1G\/2.5GBASE-X SFP transceivers\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003eConsole\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e1 x RJ45-to-RS232 serial port (115200, 8, N, 1)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003eReset Button\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e\u0026lt; 5 sec: System reboot; \u0026gt; 5 sec: Factory default\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003ePower Requirements\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eAC 100~240V, 50\/60Hz\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003ePower Consumption \/ Dissipation\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eMax. 10.7 watts\/36.5BTU power on without connection; Max. 269 watts\/917.87BTU full loading\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003eDimensions (W x D x H)\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e280 x 230 x 44mm\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003eWeight\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e1885g\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003eInstallation\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eRack mount\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003eSurge Protection\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eCommon mode 4KV, Differential mode 2KV\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003eESD Protection\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eContact Discharge 6KV DC; Air Discharge 8KV DC\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003eFan\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e1 smart fan\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003eLED\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSystem: Power LED Green, SYS LED Green; Ports: RJ45 LNK\/ACT Green, 10G SFP+ LNK\/ACT Green, PoE-in-Use Amber\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003eSwitch Architecture\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eStore-and-Forward\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003eSwitch Fabric\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e56Gbps\/non-blocking\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003eSwitch Throughput @64Bytes\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e41.66Mpps @64 bytes\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003eAddress Table\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e16K entries\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003eShared Data Buffer\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e12Mbits\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003eFlow Control\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eIEEE 802.3x pause frame for full duplex\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003eJumbo Frame\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eBack pressure for half duplex\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003ePoE Standard\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eIEEE 802.3bt PoE++ PSE; backward compatible with IEEE 802.3at\/af PoE PSE\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003ePoE Power Supply Type\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e802.3bt: End-span + Mid-span; 802.3at: End-span\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003ePoE Power Output\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003ePort 1 to 8 – 95W max.\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003ePower Pin Assignment\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e802.3bt\/UPoE: 1\/2(-), 3\/6(+), 4\/5(+), 7\/8(-); 802.3at PoE End-span: 1\/2(-), 3\/6(+)\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003ePoE Power Budget\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e240 watts max.\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003eNumber of 95W 802.3bt Type-4 PDs\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e2\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003eNumber of 60W 802.3bt Type-3 PDs\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e4\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003eNumber of 802.3at PDs\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e8\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003eEnhanced PoE Mode\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSystem PoE Admin Mode; Consumption Mode\/Allocation Mode; Temperature Threshold; Standard\/Legacy\/UPoE\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003eActive PoE Device Live Detection\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eYes\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003ePoE Power Recycling\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eYes, daily or predefined schedule\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003ePoE Schedule\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e4 schedule profiles\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003ePoE Extended Mode\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eYes, max. up to 250 meters\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003ePort Mirroring\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eTX\/RX\/both Many-to-1 monitor; up to 4 sessions\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003eVLAN\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e802.1Q tagged VLAN; 802.1ad Q-in-Q tunneling; Protocol VLAN; Private VLAN; GVRP Management; up to 256 VLAN groups out of 4094 VLAN IDs\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003eLink Aggregation\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eIEEE 802.3ad LACP and static trunk; supports 8 groups with 8 ports per trunk\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003eSpanning Tree Protocol\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eIEEE 802.1D STP, IEEE 802.1w RSTP, IEEE 802.1s MSTP, BPDU Guard, BPDU Filtering and BPDU Forwarding\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003eIGMP Snooping\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eIPv4 IGMP snooping v2\/v3; IGMP querier; up to 256 multicast groups\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003eMLD Snooping\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eIPv6 MLD snooping v1\/v2; up to 256 multicast groups\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003eQoS\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e8 mapping IDs to 8 level priority queues; port number; 802.1p priority; DSCP\/IP precedence; strict priority and WRR; ingress\/egress rate limit\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003eRing\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSupports ERPS and complies with ITU-T G.8032; recovery time \u0026lt; 450ms\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003eIP Interfaces\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eMax. 64 VLAN interfaces\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003eRouting Table\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eMax. 32 routing entries\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003eRouting Protocols\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eIPv4\/IPv6 hardware static routing\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003eAccess Control List\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eIPv4\/IPv6 IP-based ACL\/MAC-based ACL; IPv4\/IPv6 IP-based ACE\/MAC-based ACE; max. 256 ACL entries\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003ePort Security\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eBuilt-in RADIUS client; RADIUS\/TACACS+ user access authentication\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003eMAC Security\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eIP-MAC port binding; MAC filter; static MAC address max. 256 static MAC entries\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003eEnhanced Security\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eDHCP Snooping and DHCP Option82; STP BPDU guard, BPDU filtering and BPDU forwarding; DoS attack prevention; ARP inspection; IP source guard\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003eBasic Management Interfaces\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eConsole, Web browser, Telnet, SNMP v1, v2c\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003eSecure Management Interfaces\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eSSHv2, TLS v1.2, TLS v1.3, SNMP v3\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003eSystem Management\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eFirmware upgrade by HTTP\/TFTP; configuration upload\/download through HTTP\/TFTP; LLDP; SNTP; PLANET Smart Discovery Utility; PLANET NMS\/CloudNMS\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003eEvent Management\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eRemote\/Local Syslog; System log\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003eSNMP MIBs\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eRFC 1213, 1215, 1493, 2674, 2737, 2819, 2863, 3635, 3621, LLDP MIB, PLANET-Aggr-MIB, PLANET-DDMI-MIB, PLANET-Firmware-MIB, PLANET-GVRP-MIB, PLANET-LACP-MIB, PLANET-SYSUTIL-MIB, PLANET-CONFIG series MIBs\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003eRegulatory Compliance\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eFCC Part 15 Class A, CE\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003eStandards Compliance\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003eIEEE 802.3, 802.3u, 802.3z, 802.3ab, 802.3ae, 802.3x, 802.3ad, 802.1D, 802.1w, 802.1s, 802.1p, 802.1Q, 802.1ab, 802.3af, 802.3at, 802.3bt, 802.3az, RFC 768, RFC 783, RFC 791, RFC 792, RFC 2068, RFC 1112, RFC 2236, RFC 3376, RFC 2710, RFC 3810, ITU-T G.8032 ERPS Ring\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003eOperating Temperature\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e0 ~ 50 degrees C\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003eStorage Temperature\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e-10 ~ 60 degrees C\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003eHumidity\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e5 ~ 95% non-condensing\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px; background:#f9f9f9; font-weight:bold;\"\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd; padding:10px;\"\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-family: Arial, sans-serif; font-size: 14px; height: 94.5px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: rgb(242, 242, 242); font-weight: bold; height: 33.9722px;\"\u003e\n\u003cth style=\"border: 1px solid rgb(221, 221, 221); padding: 10px; height: 33.9722px;\"\u003eDescription\u003c\/th\u003e\n\u003cth style=\"border: 1px solid rgb(221, 221, 221); padding: 10px; text-align: center; height: 33.9722px;\"\u003eDownloads\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 60.5278px;\"\u003e\n\u003ctd style=\"background-color: rgb(249, 249, 249); border: 1px solid rgb(221, 221, 221); padding: 10px; height: 60.5278px;\"\u003eDatasheet\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid rgb(221, 221, 221); padding: 10px; text-align: center; height: 60.5278px;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0581\/5556\/5242\/files\/C-GS-4210-8UP2X_v1.1_L.pdf?v=1783425802\" title=\"Datasheet\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Planet","offers":[{"title":"Default Title","offer_id":46116920688826,"sku":"GS-4210-8UP2X","price":230.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0581\/5556\/5242\/files\/PlanetGS-4210-8UP2X8-Port101001000T802.3btPoE_2-Port10GSFP_ManagedEthernetSwitch_1.png?v=1783425878","url":"https:\/\/screenmoove.com\/products\/planet-gs-4210-8up2x-8-port-10-100-1000t-802-3bt-poe-2-port-10g-sfp-managed-ethernet-switch","provider":"Screen Moove","version":"1.0","type":"link"}