{"product_id":"planet-tsn-5225-4t-managed-tsn-ethernet-switch","title":"Planet TSN-5225-4T Industrial L2+ 4-Port 10\/100\/1000T Managed TSN Ethernet Switch","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eDescription\u003c\/li\u003e\n\u003cli\u003eSpecifications\u003c\/li\u003e\n\u003cli\u003eDownloads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch2 style=\"text-align: center;\"\u003ePrecision Time Synchronisation and Ultra-Low Latency for Industrial Automation\u003c\/h2\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eInnovative Industrial TSN Ethernet Switch Guarantees Delivery of Time-Sensitive Data \u003c\/strong\u003e\u003cbr\u003ePLANET TSN-5225-4T is a brand-new Industrial-grade Layer 2+ Time-Sensitive Networking (TSN) Managed Ethernet Switch which features 4 10\/100\/1000BASE-T RJ45 ports in a rugged IP30 metal case for stable operation in heavy environments, and addresses all levels of the industrial automation network, from the field bus to the factory backbone. And it guarantees end-to-end transmission of high-priority traffic with extremely low latency. \u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eThe TSN-5225-4T can be installed in any difficult environment as it can operate stably under the temperature range from -40 to 75 degrees C. It also allows either DIN-rail or wall mounting for efficient use of cabinet space.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eBuilding a Sustainable Future for Innovation with ESG Principles\u003c\/strong\u003e\u003cbr\u003eThe TSN-5225-4T can help businesses achieve more efficient operations and production while reducing energy consumption and resource wastage, thereby enhancing both the economic and social benefits of the enterprise, aligning with the core values of ESG. For instance, the application of the TSN-5225-4T in industrial automation enables precise control of the manufacturing process, reducing energy consumption and waste generation. Similarly, their use in transportation can optimize logistics routes, mitigating issues such as carbon emissions and traffic congestion.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eA Simplified Pathway to a TSN-compatible Infrastructure\u003c\/strong\u003e\u003cbr\u003ePLANET TSN-5225-4T provides real-time, low-latency network communication for industrial automation, 5G NR networks, Industry 4.0, 4K\/8K video streaming, and VR\/AR gaming industry by using the Time-sensitive Networking (TSN) technology and IEEE 1588 Precision Time Protocol (PTPv2) for time synchronization on all ports. \u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eThe TSN-5225-4T supports TSN IEEE standards needed for a complete real-time communication solution. These include IEEE 802.1AS-REV profile for time synchronization, IEEE 802.1Qbv for Enhancements for Scheduled Traffic, IEEE 802.1Qbu Frame Preemption, IEEE 802.3br Interspersing Express Traffic (IET), IEEE 802.1Qci for per-stream filtering and policing (PSFP) and IEEE 802.1CB frame replication and elimination for reliability (FRER) for seamless redundancy.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eThe TSN-5225-4T eliminates the need for separating information technology (IT) and operational technology (OT) Ethernet networks, providing a more ubiquitous approach to synchronization and precision timing for today’s industrial automation systems. \u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0581\/5556\/5242\/files\/Planet_TSN-5225-4T_Industrial_L2_4-Port_101001000T_Managed_TSN_Ethernet_Switch_12.png?v=1794321206\" alt=\"\"\u003e\u003cbr\u003e1588 Time Protocol for Industrial Computing Networks\u003c\/strong\u003e\u003cbr\u003eThe TSN-5225-4T features IEEE 1588v2 PTP (Precision Time Protocol) with hardware-based time stamping for precise time synchronization of networks, and support for Boundary Clock, End to End and Peer to Peer Transparent Clock modes. It is ideal for telecom and carrier Ethernet applications, supporting MEF service delivery and timing over packet solutions for IEEE 1588 and synchronous Ethernet.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0581\/5556\/5242\/files\/Planet_TSN-5225-4T_Industrial_L2_4-Port_101001000T_Managed_TSN_Ethernet_Switch_11.png?v=1794321206\" alt=\"\"\u003e\u003cbr\u003eRedundant Ring, Fast Recovery for Critical Network Applications\u003c\/strong\u003e\u003cbr\u003eThe TSN-5225-4T supports redundant ring technology and features strong, rapid self-recovery capability to prevent interruptions and external intrusions. It incorporates advanced ITU-T G.8032 ERPS (Ethernet Ring Protection Switching) technology, Spanning Tree Protocol (802.1s MSTP), and redundant power input system into customer’s industrial automation network to enhance system reliability and uptime in harsh factory environments. In a simple ring network, the recovery time of data link can be as fast as 10ms.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0581\/5556\/5242\/files\/Planet_TSN-5225-4T_Industrial_L2_4-Port_101001000T_Managed_TSN_Ethernet_Switch_10.png?v=1794321206\" alt=\"\"\u003e\u003cbr\u003eRobust Layer 2 Features\u003c\/strong\u003e\u003cbr\u003eThe TSN-5225-4T can be programmed for advanced Layer 2 switch management functions such as dynamic port link aggregation, 802.1Q tagged VLAN, Q-in-Q VLAN, private VLAN, Multiple Spanning Tree Protocol (MSTP), Layer 2 to Layer 4 QoS, bandwidth control, IGMP snooping and MLD snooping. Via the aggregation of supporting ports, the TSN-5225-4T allows the operation of a high-speed trunk group that comes with multiple ports and supports fail-over as well.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0581\/5556\/5242\/files\/Planet_TSN-5225-4T_Industrial_L2_4-Port_101001000T_Managed_TSN_Ethernet_Switch_9.png?v=1794321206\" alt=\"\"\u003e\u003cbr\u003eCybersecurity Network Solution to Minimize Security Risks\u003c\/strong\u003e\u003cbr\u003eThe cybersecurity features that virtually need no effort and cost to have include the protection of the switch management and the enhanced security of the mission-critical network. Both SSHv2 and TLSv1.2 protocols are utilized to provide strong protection against advanced threats. The network administrator can now construct highly-secure corporate networks with considerably less time and effort than before.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0581\/5556\/5242\/files\/Planet_TSN-5225-4T_Industrial_L2_4-Port_101001000T_Managed_TSN_Ethernet_Switch_8.png?v=1794321206\" alt=\"\"\u003e\u003cbr\u003eModbus TCP Provides Flexible Network Connectivity for Factory Automation\u003c\/strong\u003e\u003cbr\u003eWith the supported Modbus TCP\/IP protocol, the TSN-5225-4T can easily integrate with SCADA systems, HMI systems and other data acquisition systems in factory floors. It enables administrators to remotely monitor the industrial Ethernet switch’s operating information, port information, communication status, and DI and DO status, thus easily achieving enhanced monitoring and maintenance of the entire factory.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eSMTP\/SNMP Trap Event Alert\u003c\/strong\u003e\u003cbr\u003eThe TSN-5225-4T provides event alert function to help to diagnose the abnormal device owing to whether or not there is a break of the network connection, or the rebooting response.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0581\/5556\/5242\/files\/Planet_TSN-5225-4T_Industrial_L2_4-Port_101001000T_Managed_TSN_Ethernet_Switch_7.png?v=1794321206\" alt=\"\"\u003e\u003cbr\u003eEffective Alarm Alert for Better Protection\u003c\/strong\u003e\u003cbr\u003eThe TSN-5225-4T supports a Fault Alarm feature which can alert the users when there is something wrong with the switches. With this ideal feature, the users would not have to waste time to find where the problem is. It will help to save time and human resource.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0581\/5556\/5242\/files\/Planet_TSN-5225-4T_Industrial_L2_4-Port_101001000T_Managed_TSN_Ethernet_Switch_6.png?v=1794321206\" alt=\"\"\u003e\u003cbr\u003eDigital Input and Digital Output for External Alarm\u003c\/strong\u003e\u003cbr\u003eThe TSN-5225-4T supports Digital Input and Digital Output on its front panel. This external alarm enables users to use Digital Input to detect and log external device status (such as door intrusion detector), and send event alarm to the administrators. The Digital Output could be used to alarm the administrators if the TSN-5225-4T’s port shows link down, link up or power failure.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0581\/5556\/5242\/files\/Planet_TSN-5225-4T_Industrial_L2_4-Port_101001000T_Managed_TSN_Ethernet_Switch_5.png?v=1794321206\" alt=\"\"\u003e\u003cbr\u003eIPv6\/IPv4 Dual Stack\u003c\/strong\u003e\u003cbr\u003eSupporting both IPv6 and IPv4 protocols, the TSN-5225-4T helps data centers, campuses, telecoms, and more to experience the IPv6 era with the lowest investment as its network facilities need not be replaced or overhauled if the IPv6 FTTx edge network is set up. \u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0581\/5556\/5242\/files\/Planet_TSN-5225-4T_Industrial_L2_4-Port_101001000T_Managed_TSN_Ethernet_Switch_4.png?v=1794321206\" alt=\"\"\u003e\u003cbr\u003eEfficient Management\u003c\/strong\u003e\u003cbr\u003eFor efficient management, the TSN-5225-4T is equipped with console, Web and SNMP management interfaces. \u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eWith the built-in Web-based management interface, the TSN-5225-4T offers an easy-to-use, platform-independent management and configuration facility. \u003cbr\u003eFor text-based management, it can be accessed via Telnet and the console port. \u003cbr\u003eFor standard-based monitor and management software, it offers SNMPv3 connection which encrypts the packet content at each session for secure remote management.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0581\/5556\/5242\/files\/Planet_TSN-5225-4T_Industrial_L2_4-Port_101001000T_Managed_TSN_Ethernet_Switch_3.png?v=1794321206\" alt=\"\"\u003e\u003cbr\u003ePowerful Network Security\u003c\/strong\u003e\u003cbr\u003eThe TSN-5225-4T offers comprehensive Layer 2 to Layer 4 Access Control List (ACL) for enforcing security to the edge. It can be used to restrict network access by denying packets based on source and destination IP address, TCP\/UDP ports or defined typical network applications. Its protection mechanism also comprises 802.1X Port-based and MAC-based user and device authentication. With the private VLAN function, communication between edge ports can be prevented to ensure user privacy.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eAdvanced IP Network Protection\u003c\/strong\u003e\u003cbr\u003eThe TSN-5225-4T also provides DHCP Snooping, IP Source Guard and Dynamic ARP Inspection functions to prevent IP snooping from attack and discard ARP packets with invalid MAC address. The network administrators can now construct highly-secure corporate networks with considerably less time and effort than before.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eExcellent Traffic Control\u003c\/strong\u003e\u003cbr\u003eThe TSN-5225-4T is loaded with powerful traffic management and QoS features to enhance connection services by telecoms and ISPs. The QoS features include wire-speed Layer 4 traffic classifiers and bandwidth limit that are particularly useful for multi-tenant units, multi-business units, Telco and network service providers’ applications. It also empowers the industrial environment to take full advantage of the limited network resources and guarantees the best performance in VoIP and video conferencing transmission.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eLayer 3 IPv4 and IPv6 Software VLAN Routing for Secure and Flexible Management\u003c\/strong\u003e\u003cbr\u003eTo help customers stay on top of their businesses, the TSN-5225-4T not only provides ultra high transmission performance and excellent Layer 2 technologies, but also IPv4\/IPv6 software VLAN routing feature which allows to crossover different VLANs and different IP addresses for the purpose of having a highly-secure, flexible management and simpler networking application.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eRemote Management Solution\u003c\/strong\u003e\u003cbr\u003ePLANET's Universal Network Management System (UNI-NMS) and NMSViewerPro\/CloudViewerPro app support IT staff by remotely managing all network devices and monitoring PDs' operational statuses. Thus, they're designed for both the enterprises and industries where deployments of PDs can be as remote as possible, without having to go to the actual location once a bug or faulty condition is found. With the UNI-NMS or NMSViewerPro\/CloudViewerPro app, all kinds of businesses can now be speedily and efficiently managed from one platform.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0581\/5556\/5242\/files\/Planet_TSN-5225-4T_Industrial_L2_4-Port_101001000T_Managed_TSN_Ethernet_Switch_2.png?v=1794321206\" alt=\"\"\u003e\u003cbr\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eTSN Technology for Efficient Real-time Monitoring of Factory Production Processes\u003c\/strong\u003e\u003cbr\u003ePLANET TSN-5225-4T, based on its advanced Time-Sensitive Networking (TSN) technology and utilizing IEEE 1588 Precision Time Protocol (PTPv2) for time synchronization on all ports, provides an efficient solution. Leveraging real-time data monitoring and low-latency data transmission advantages, it can be used for real-time monitoring and management of factory production processes. This system harnesses the performance of TSN to enhance production efficiency, optimize resources, and enable quick response to faults, making it a highly promising solution.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0581\/5556\/5242\/files\/Planet_TSN-5225-4T_Industrial_L2_4-Port_101001000T_Managed_TSN_Ethernet_Switch_1.png?v=1794321206\" alt=\"\"\u003e\u003cbr\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003ePhysical Port\u003c\/strong\u003e\u003cbr\u003e4 10\/100\/1000BASE-T Gigabit Ethernet RJ45 ports \u003cbr\u003eOne RJ45 console interface for basic management and setup\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eIndustrial Case and Installation\u003c\/strong\u003e\u003cbr\u003eDual power input, redundant power with reverse polarity protection\u003cbr\u003eDC 9 to 48V input or AC 24V input\u003cbr\u003eActive-active redundant power failure protection\u003cbr\u003eBackup of catastrophic power failure on one supply\u003cbr\u003eFault tolerance and resilience\u003cbr\u003eIP30 metal case \u003cbr\u003eDIN-rail and wall-mount designs\u003cbr\u003eSupports 5000V DC Ethernet ESD protection\u003cbr\u003e-40 to 75 degrees C operating temperature \u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eDigital Input and Digital Output \u003c\/strong\u003e\u003cbr\u003e2 digital input (DI)\u003cbr\u003e2 digital output (DO)\u003cbr\u003eIntegrates sensors into auto alarm system\u003cbr\u003eTransfers alarm to IP network via email and SNMP trap\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eTime Sensitive Networking \u003c\/strong\u003e\u003cbr\u003eHigh Precision Time Synchronization\u003cbr\u003eIEEE1588 (Time Stamping)\u003cbr\u003e802.1AS-Rev gPTP default profile\u003cbr\u003eShapers\u003cbr\u003e802.1Qbv Enhancements for Scheduled Traffic\u003cbr\u003e802.1Qch (Cyclic Queuing and Forwarding)\u003cbr\u003eTSN Stream Policing\u003cbr\u003e802.1Qci (Per Stream Filtering and Policing)\u003cbr\u003eRedundancy\u003cbr\u003e802.1CB FRER for seamless redundancy\u003cbr\u003eAlso standard Linear and Ring protection\u003cbr\u003eDelay Reduction\u003cbr\u003eIEEE 802.1Qbu Frame Preemption,\u003cbr\u003eIEEE 802.3br Interspersing Express Traffic (IET)\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eLayer 2 Features\u003c\/strong\u003e\u003cbr\u003ePrevents packet loss with back pressure (half-duplex) and IEEE 802.3x pause frame flow control (full-duplex)\u003cbr\u003eHigh performance of Store-and-Forward architecture, and runt\/CRC filtering eliminates erroneous packets to optimize the network bandwidth\u003cbr\u003eStorm Control support\u003cbr\u003eBroadcast\/Multicast\/Unicast\u003cbr\u003eSupports VLAN\u003cbr\u003eIEEE 802.1Q tagged VLAN\u003cbr\u003eSupports provider Bridging (VLAN Q-in-Q, IEEE 802.1ad) \u003cbr\u003ePrivate VLAN Edge (PVE)\u003cbr\u003ePort Isolation\u003cbr\u003eMAC-based VLAN\u003cbr\u003eProtocol-based VLAN\u003cbr\u003eVoice VLAN\u003cbr\u003eVLAN Translation\u003cbr\u003eGVRP\u003cbr\u003eSupports Spanning Tree Protocol\u003cbr\u003eIEEE 802.1D Spanning Tree Protocol (STP)\u003cbr\u003eIEEE 802.1w Rapid Spanning Tree Protocol (RSTP)\u003cbr\u003eIEEE 802.1s Multiple Spanning Tree Protocol (MSTP), spanning tree by VLAN\u003cbr\u003eBPDU Guard\u003cbr\u003eSupports Link Aggregation\u003cbr\u003e802.3ad Link Aggregation Control Protocol (LACP)\u003cbr\u003eCisco ether-channel (static trunk)\u003cbr\u003eMaximum2 trunk groups with 4 ports per trunk group \u003cbr\u003eProvides port mirror (many-to-1)\u003cbr\u003ePort mirroring to monitor the incoming or outgoing traffic on a particular port \u003cbr\u003eLoop protection to avoid broadcast loops\u003cbr\u003eSupports ERPS (Ethernet Ring Protection Switching)\u003cbr\u003eCompatible with Cisco Uni-directional link detection(UDLD) that monitors a link between two switches and blocks the ports on both ends of the link if the link fails at any point between the two devices\u003cbr\u003eLink Layer Discovery Protocol (LLDP) and LLDP-MED\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eLayer 3 IP Routing Features\u003c\/strong\u003e\u003cbr\u003eSupports maximum 32 static routes and route summarization\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eQuality of Service\u003c\/strong\u003e\u003cbr\u003eIngress Shaper and Egress Rate Limit per port bandwidth control\u003cbr\u003e8 priority queues on all switch ports\u003cbr\u003eTraffic classification\u003cbr\u003eIEEE 802.1p CoS\u003cbr\u003eIP TOS\/DSCP\/IP precedence\u003cbr\u003eIP TCP\/UDP port number\u003cbr\u003eTypical network application\u003cbr\u003eStrict priority and Weighted Round Robin (WRR) CoS policies\u003cbr\u003eSupports QoS and In\/Out bandwidth control on each port\u003cbr\u003eraffic-policing on the switch port\u003cbr\u003eDSCP remarking\u003cbr\u003eVoice VLAN\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eMulticast\u003c\/strong\u003e\u003cbr\u003eSupports IPv4 IGMP snooping v1, v2 and v3\u003cbr\u003eSupports IPv6 MLD snooping v1 and v2\u003cbr\u003eQuerier mode support\u003cbr\u003eIPv4 IGMP snooping port filtering\u003cbr\u003eIPv6 MLD snooping port filtering\u003cbr\u003eMulticast VLAN Registration (MVR) support\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eSecurity\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eAuthentication\u003c\/strong\u003e\u003cbr\u003eIEEE 802.1x Port-based\/MAC-based network access authentication\u003cbr\u003eBuilt-in RADIUS client to co-operate with the RADIUS servers\u003cbr\u003eTACACS+ login users access authentication\u003cbr\u003eRADIUS\/TACACS+ users access authentication\u003cbr\u003eAccess Control List\u003cbr\u003eIP-based Access Control List (ACL)\u003cbr\u003eMAC-based Access Control List\u003cbr\u003eSource MAC\/IP address binding\u003cbr\u003eDHCP Snooping to filter un-trusted DHCP messages\u003cbr\u003eDynamic ARP Inspection discards ARP packets with invalid MAC address to IP address binding\u003cbr\u003eIP Source Guard prevents IP spoofing attacks\u003cbr\u003eIP address access management to prevent unauthorized intruder\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eManagement\u003c\/strong\u003e\u003cbr\u003eIPv4 and IPv6 dual stack management\u003cbr\u003eSwitch Management Interfaces\u003cbr\u003eConsole\/Telnet Command Line Interface \u003cbr\u003eWeb switch management\u003cbr\u003eSNMP v1, v2c, and v3 switch management\u003cbr\u003eSSHv2 and TLSv1.2 secure access\u003cbr\u003eIPv6 IP Address\/NTP\/DNS management\u003cbr\u003eBuilt-in Trivial File Transfer Protocol (TFTP) client\u003cbr\u003eBOOTP and DHCP for IP address assignment\u003cbr\u003eSystem Maintenance\u003cbr\u003eFirmware upload\/download via HTTP\u003cbr\u003eConfiguration upload\/download through HTTP\u003cbr\u003eReset button for system reboot or reset to factory default\u003cbr\u003eDual Images\u003cbr\u003eDHCP Relay\u003cbr\u003eDHCP Option82\u003cbr\u003eDHCP Server Mode support\u003cbr\u003eUser Privilege levels control\u003cbr\u003eNTP (Network Time Protocol)\u003cbr\u003eNetwork Diagnostic\u003cbr\u003eICMPv6\/ICMPv4 Remote Ping\u003cbr\u003eSMTP\/Syslog remote alarm\u003cbr\u003eFour RMON groups (history, statistics, alarms and events) \u003cbr\u003eSNMP trap for interface Link up and Link down notification\u003cbr\u003eSystem Log\u003cbr\u003ePLANET Smart Discovery Utility for deployment management\u003cbr\u003ePLANET NMS comes with NMSViewerPro and CloudViewerPro applications for deployment management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-family: Arial,sans-serif; font-size: 14px; color: #333; table-layout: fixed; line-height: 1.5;\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"width: 18%;\"\u003e \u003ccol style=\"width: 32%;\"\u003e \u003ccol style=\"width: 18%;\"\u003e \u003ccol style=\"width: 32%;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" style=\"padding: 10px; border: 1px solid #ddd; background-color: #f0f0f0; font-weight: bold;\"\u003eHardware Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold; vertical-align: top;\"\u003eCopper Ports\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; vertical-align: top; overflow-wrap: anywhere;\"\u003e4 10\/100\/1000BASE-T RJ45 auto-MDI\/MDI-X ports\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold; vertical-align: top;\"\u003eConsole\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; vertical-align: top;\"\u003e1 x RJ45-to-RS232 serial port (115200, 8, N, 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold; vertical-align: top;\"\u003eReset Button\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; vertical-align: top;\"\u003e\u0026lt; 5 sec: System reboot\u003cbr\u003e\u0026gt; 5 sec: Factory default\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold; vertical-align: top;\"\u003eConnector\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; vertical-align: top;\"\u003eRemovable 6-pin terminal block for power input\u003cbr\u003ePin 1\/2 for Power 1, Pin 3\/4 for fault alarm, Pin 5\/6 for Power 2\u003cbr\u003eRemovable 6-pin terminal block for DI\/DO interface\u003cbr\u003ePin 1\/2 for DI 1 \u0026amp; 2, Pin 3\/4 for DO 1 \u0026amp; 2, Pin 5\/6 for GND\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold; vertical-align: top;\"\u003eAlarm\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; vertical-align: top;\"\u003eOne relay output for power failure. Alarm relay current carry ability: 1A @ 24V DC\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold; vertical-align: top;\"\u003eDigital Input (DI)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; vertical-align: top;\"\u003e2 digital input:\u003cbr\u003eLevel 0: -24~2.1V (±0.1V)\u003cbr\u003eLevel 1: 2.1~24V (±0.1V)\u003cbr\u003eInput load to 24V DC, 10mA max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold; vertical-align: top;\"\u003eDigital Output (DO)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; vertical-align: top;\"\u003e2 digital output:\u003cbr\u003eOpen collector to 24VDC, 100mA\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold; vertical-align: top;\"\u003eEnclosure\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; vertical-align: top;\"\u003eIP30 aluminum case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003eInstallation\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eDIN-rail or wall mounting\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003eSDRAM\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e1024Mbytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003eFlash Memory\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e64Mbytes\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e60 x 135 x 135 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e962g\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003ePower Requirements\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eDC 9~48V, 1.5A max.\u003cbr\u003eAC 24V, 1A max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold; vertical-align: top;\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; vertical-align: top;\"\u003e\n\u003cstrong\u003eDC input:\u003c\/strong\u003e\u003cbr\u003eMax. 8.36 watts\/28.53BTU (system on)\u003cbr\u003eMax. 9.89 watts\/33.75BTU (Full loading)\u003cbr\u003e\u003cstrong\u003eAC 24V input:\u003c\/strong\u003e\u003cbr\u003eMax. 6.2 watts\/21.16BTU (system on)\u003cbr\u003eMax. 7.9 watts\/26.96BTU (Full loading)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold; vertical-align: top;\"\u003eESD Protection\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; vertical-align: top;\"\u003e5KV DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold; vertical-align: top;\"\u003eSurge Protection\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; vertical-align: top;\"\u003e6KV DC\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold; vertical-align: top;\"\u003eLED Indicators\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; vertical-align: top;\"\u003e\n\u003cstrong\u003eSystem:\u003c\/strong\u003e\u003cbr\u003ePower 1 (Green), Power 2 (Green)\u003cbr\u003eFault Alarm (Red)\u003cbr\u003eRing (Green), Ring Owner (Green)\u003cbr\u003eDIDO (Red)\u003cbr\u003e\u003cstrong\u003ePer 10\/100\/1000T RJ45 Port:\u003c\/strong\u003e\u003cbr\u003e1000Mbps LNK\/ACT (Green)\u003cbr\u003e10\/100Mbps LNK\/ACT (Amber)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" style=\"padding: 10px; border: 1px solid #ddd; background-color: #f0f0f0; font-weight: bold;\"\u003eSwitching Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003eSwitch Architecture\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eStore-and-Forward\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003eSwitch Fabric\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e8Gbps\/non-blocking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003eThroughput\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e5.95Mpps@64Bytes\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003eAddress Table\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e8K entries, automatic source address learning and aging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003eShared Data Buffer\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e32Mbits\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003eJumbo Frame\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e10K bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003eFlow Control\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eIEEE 802.3x pause frame for full duplex\u003cbr\u003eBack pressure for half duplex\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" style=\"padding: 10px; border: 1px solid #ddd; background-color: #f0f0f0; font-weight: bold;\"\u003eLayer 3 Functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003eIP Interfaces\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eMax. 8 VLAN interfaces\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003eRouting Table\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eMax. 32 routing entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003eRouting Protocols\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eIPv4 software static routing\u003cbr\u003eIPv6 software static routing\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" style=\"padding: 10px; border: 1px solid #ddd; background-color: #f0f0f0; font-weight: bold;\"\u003eLayer 2 Functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold; vertical-align: top;\"\u003ePort Configuration\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; vertical-align: top;\"\u003ePort disable\/enable\u003cbr\u003eAuto-negotiation 10\/100\/1000Mbps full and half duplex mode selection\u003cbr\u003eFlow control disable\/enable\u003cbr\u003ePort link capability control\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold; vertical-align: top;\"\u003ePort Status\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; vertical-align: top;\"\u003eDisplay each port’s speed duplex mode, link status, flow control status, auto-negotiation status, trunk status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold; vertical-align: top;\"\u003ePort Mirroring\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; vertical-align: top;\"\u003eTX\/RX\/Both\u003cbr\u003eMany-to-1 monitor\u003cbr\u003eMirror – Remote Switched Port Analyzer (Cisco RSPAN)\u003cbr\u003eSupports up to 5 sessions\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold; vertical-align: top;\"\u003eVLAN\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; vertical-align: top;\"\u003eIEEE 802.1Q tagged VLAN\u003cbr\u003eIEEE 802.1ad Q-in-Q tunneling\u003cbr\u003ePrivate VLAN Edge (PVE)\u003cbr\u003eMAC-based VLAN\u003cbr\u003eProtocol-based VLAN\u003cbr\u003eVoice VLAN\u003cbr\u003eIP Subnet-based VLAN\u003cbr\u003eMVR (Multicast VLAN registration)\u003cbr\u003eGVRP\u003cbr\u003eUp to 4K VLAN groups, out of 4096 VLAN IDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold; vertical-align: top;\"\u003eLink Aggregation\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; vertical-align: top;\"\u003eIEEE 802.3ad LACP\/static trunk\u003cbr\u003eMaximum 2 trunk groups with 4 ports per trunk group\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold; vertical-align: top;\"\u003eSpanning Tree Protocol\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; vertical-align: top;\"\u003eIEEE 802.1D Spanning Tree Protocol\u003cbr\u003eIEEE 802.1w Rapid Spanning Tree Protocol\u003cbr\u003eIEEE 802.1s Multiple Spanning Tree Protocol\u003cbr\u003eBPDU Guard, BPDU filtering and BPDU transparent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold; vertical-align: top;\"\u003eIGMP Snooping\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; vertical-align: top;\"\u003eIPv4 IGMP (v1\/v2\/v3) snooping\u003cbr\u003eIPv4 IGMP querier mode support\u003cbr\u003eSupports 255 IGMP groups\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold; vertical-align: top;\"\u003eMLD Snooping\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; vertical-align: top;\"\u003eIPv6 MLD (v1\/v2) snooping\u003cbr\u003eIPv6 MLD querier mode support\u003cbr\u003eSupports 255 MLD groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold; vertical-align: top;\"\u003eBandwidth Control\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; vertical-align: top;\"\u003ePer port bandwidth control\u003cbr\u003eIngress: 100Kb~3276Mbps\u003cbr\u003eEgress: 100Kb~3281Mbps\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold; vertical-align: top;\"\u003eRing\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; vertical-align: top;\"\u003eSupports ERPS, and complies with ITU-T G.8032\u003cbr\u003eRecovery time \u0026lt; 10ms @ 3 nodes\u003cbr\u003eRecovery time \u0026lt; 50ms @ 16 nodes\u003cbr\u003eSupports Major ring and sub-ring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold; vertical-align: top;\"\u003eSynchronization\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; vertical-align: top;\"\u003eIEEE 1588v2 PTP (Precision Time Protocol)\u003cbr\u003ePTP Master\u003cbr\u003ePTP Slave\u003cbr\u003eBoundary clock\u003cbr\u003eOrdinary Clock\u003cbr\u003ePeer-to-peer transparent clock\u003cbr\u003eEnd-to-end transparent clock\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold; vertical-align: top;\"\u003eQoS\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; vertical-align: top;\"\u003eIngress Shaper and Egress Rate Limit per port bandwidth control\u003cbr\u003e8 priority queues on all switch ports\u003cbr\u003eTraffic classification:\u003cbr\u003eIEEE 802.1p CoS\u003cbr\u003eIP TOS \/ DSCP \/ IP Precedence\u003cbr\u003eIP TCP\/UDP port number\u003cbr\u003eTypical network application\u003cbr\u003eTraffic-policing policies on the switch port\u003cbr\u003eDSCP remarking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold; vertical-align: top;\"\u003eTime-Sensitive Networking Protocols\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; vertical-align: top;\"\u003e\n\u003cstrong\u003eHigh Precision Time Synchronization:\u003c\/strong\u003e\u003cbr\u003eIEEE1588 (Time Stamping)\u003cbr\u003e802.1AS-Rev gPTP default profile\u003cbr\u003e\u003cstrong\u003eShapers:\u003c\/strong\u003e\u003cbr\u003e802.1Qbv (Time-aware Scheduling)\u003cbr\u003e802.1Qch (Cyclic Queuing and Forwarding)\u003cbr\u003e\u003cstrong\u003eTSN Stream Policing:\u003c\/strong\u003e\u003cbr\u003e802.1Qci (Per Stream Filtering and Policing)\u003cbr\u003e\u003cstrong\u003eRedundancy:\u003c\/strong\u003e\u003cbr\u003e802.1CB (Frame Replication and Elimination for Redundancy for seamless redundancy)\u003cbr\u003eAlso standard Linear and Ring protection\u003cbr\u003e\u003cstrong\u003eDelay Reduction:\u003c\/strong\u003e\u003cbr\u003eIEEE 802.1Qbu Frame Preemption\u003cbr\u003eIEEE 802.3br Interspersing Express Traffic (IET)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" style=\"padding: 10px; border: 1px solid #ddd; background-color: #f0f0f0; font-weight: bold;\"\u003eSecurity Functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold; vertical-align: top;\"\u003eAccess Control List\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; vertical-align: top;\"\u003eIP-based ACL\/MAC-based ACL\u003cbr\u003eACL based on:\u003cbr\u003eMAC Address\u003cbr\u003eIP Address\u003cbr\u003eEthertype\u003cbr\u003eProtocol Type\u003cbr\u003eVLAN ID\u003cbr\u003eDSCP\u003cbr\u003e802.1p Priority\u003cbr\u003eUp to 512 entries\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold; vertical-align: top;\"\u003eSecurity\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; vertical-align: top;\"\u003ePort security\u003cbr\u003eIP source guard, up to 512 entries\u003cbr\u003eDynamic ARP inspection, up to 1K entries\u003cbr\u003eCommand line authority control based on user level\u003cbr\u003eStatic MAC address, up to 64 entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold; vertical-align: top;\"\u003eAAA\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; vertical-align: top;\"\u003eRADIUS client\u003cbr\u003eTACACS+ client\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold; vertical-align: top;\"\u003eNetwork Access Control\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; vertical-align: top;\"\u003eIEEE 802.1x port-based network access control\u003cbr\u003eMAC-based authentication\u003cbr\u003eLocal\/RADIUS authentication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" style=\"padding: 10px; border: 1px solid #ddd; background-color: #f0f0f0; font-weight: bold;\"\u003eManagement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold; vertical-align: top;\"\u003eBasic Management Interfaces\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; vertical-align: top;\"\u003eConsole; Telnet; Web browser; SNMP v1, v2c\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold; vertical-align: top;\"\u003eSecure Management Interfaces\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; vertical-align: top;\"\u003eSSHv2, TLSv1.2, SNMPv3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold; vertical-align: top;\"\u003eSystem Management\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; vertical-align: top;\"\u003eFirmware upgrade by HTTP protocol through Ethernet network\u003cbr\u003eConfiguration upload\/download through HTTP\u003cbr\u003eRemote Syslog\u003cbr\u003eSystem log\u003cbr\u003eLLDP protocol\u003cbr\u003eNTP\u003cbr\u003ePLANET Smart Discovery Utility\u003cbr\u003ePLANET NMS\u003cbr\u003ePLANET NMSViewerPro\/CloudViewerPro\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold; vertical-align: top;\"\u003eEvent Management\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; vertical-align: top;\"\u003eRemote syslog\u003cbr\u003eLocal system log\u003cbr\u003eSMTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold; vertical-align: top;\"\u003eSNMP MIBs\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; vertical-align: top; overflow-wrap: anywhere;\"\u003eRFC 1213 MIB-II\u003cbr\u003eRFC 1493 Bridge MIB\u003cbr\u003eRFC 1643 Ethernet MIB\u003cbr\u003eRFC 2863 Interface MIB\u003cbr\u003eRFC 2665 Ether-Like MIB\u003cbr\u003eRFC 2819 RMON MIB (Group 1, 2, 3 and 9)\u003cbr\u003eRFC 2737 Entity MIB\u003cbr\u003eRFC 2618 RADIUS Client MIB\u003cbr\u003eRFC 2863 IF-MIB\u003cbr\u003eRFC 2933 IGMP-STD-MIB\u003cbr\u003eRFC 3411 SNMP-Frameworks-MIB\u003cbr\u003eRFC 4292 IP Forward MIB\u003cbr\u003eRFC 4293 IP MIB\u003cbr\u003eRFC 4836 MAU-MIB\u003cbr\u003eIEEE 802.1X PAE\u003cbr\u003eLLDP\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" style=\"padding: 10px; border: 1px solid #ddd; background-color: #f0f0f0; font-weight: bold;\"\u003eStandards Conformance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold; vertical-align: top;\"\u003eRegulatory Compliance\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; vertical-align: top;\"\u003eFCC Part 15 Class A\u003cbr\u003eCE:\u003cbr\u003eEN55032\u003cbr\u003eEN55035\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold; vertical-align: top;\"\u003eStability Testing\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; vertical-align: top;\"\u003eIEC60068-2-32 (free fall)\u003cbr\u003eIEC60068-2-27 (shock)\u003cbr\u003eIEC60068-2-6 (vibration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold; vertical-align: top;\"\u003eStandards Compliance\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; vertical-align: top; overflow-wrap: anywhere;\"\u003eIEEE 802.3 10BASE-T\u003cbr\u003eIEEE 802.3u 100BASE-TX\/100BASE-FX\u003cbr\u003eIEEE 802.3ab Gigabit 1000T\u003cbr\u003eIEEE 802.3x flow control and back pressure\u003cbr\u003eIEEE 802.3ad port trunk with LACP\u003cbr\u003eIEEE 802.1D Spanning Tree Protocol\u003cbr\u003eIEEE 802.1w Rapid Spanning Tree Protocol\u003cbr\u003eIEEE 802.1s Multiple Spanning Tree Protocol\u003cbr\u003eIEEE 802.1p Class of Service\u003cbr\u003eIEEE 802.1Q VLAN tagging\u003cbr\u003eIEEE 802.1X Port Authentication Network Control\u003cbr\u003eIEEE 802.1ab LLDP\u003cbr\u003eIEEE 802.3ah OAM\u003cbr\u003eIEEE 1588 PTPv2\u003cbr\u003eIEEE 802.1ag Connectivity Fault Management (CFM)\u003cbr\u003eIEEE 802.1AS - Timing and Synchronization for Time-sensitive Applications\u003cbr\u003eIEEE 802.1Qbu Frame Preemption\u003cbr\u003eIEEE 802.3br Interspersing Express Traffic (IET)\u003cbr\u003eIEEE 802.1Qci Per-Stream Filtering and Policing (PSFP)\u003cbr\u003eIEEE 802.1Qbv Enhancements for Scheduled Traffic\u003cbr\u003eIEEE 802.1CB Frame Replication and Elimination for Reliability (FRER)\u003cbr\u003eRFC 768 UDP\u003cbr\u003eRFC 783 TFTP\u003cbr\u003eRFC 791 IP\u003cbr\u003eRFC 792 ICMP\u003cbr\u003eRFC 2068 HTTP\u003cbr\u003eRFC 1112 IGMP v1\u003cbr\u003eRFC 2236 IGMP v2\u003cbr\u003eRFC 3376 IGMP v3\u003cbr\u003eRFC 2710 MLD v1\u003cbr\u003eRFC 3810 MLD v2\u003cbr\u003eITU-T G.8032 ERPS Ring\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" style=\"padding: 10px; border: 1px solid #ddd; background-color: #f0f0f0; font-weight: bold;\"\u003eEnvironment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003eOperating\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e-40 ~ 75 degrees C\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003eStorage\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e-40 ~ 85 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003eHumidity\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e5 ~ 95% (non-condensing)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #f9f9f9; font-weight: bold;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-family: Arial, sans-serif; font-size: 14px; height: 94.5px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: rgb(242, 242, 242); font-weight: bold; height: 33.9722px;\"\u003e\n\u003cth style=\"border: 1px solid rgb(221, 221, 221); padding: 10px; height: 33.9722px;\"\u003eDescription\u003c\/th\u003e\n\u003cth style=\"border: 1px solid rgb(221, 221, 221); padding: 10px; text-align: center; height: 33.9722px;\"\u003eDownloads\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 60.5278px;\"\u003e\n\u003ctd style=\"background-color: rgb(249, 249, 249); border: 1px solid rgb(221, 221, 221); padding: 10px; height: 60.5278px;\"\u003eDatasheet\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid rgb(221, 221, 221); padding: 10px; text-align: center; height: 60.5278px;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0581\/5556\/5242\/files\/C-TSN-5225-4T_L.pdf?v=1794321456\" title=\"Datasheet\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Planet","offers":[{"title":"Default Title","offer_id":50997729362106,"sku":"TSN-5225-4T","price":430.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0581\/5556\/5242\/files\/3PlanetTSN-5225-4TIndustrialL2_4-Port101001000TManagedTSNEthernetSwitch_3.jpg?v=1794321511","url":"https:\/\/screenmoove.com\/products\/planet-tsn-5225-4t-managed-tsn-ethernet-switch","provider":"Screen Moove","version":"1.0","type":"link"}