Planet RS232/RS422/RS485 Serial Device Server | ICS-110
SKU: ICS-110
£69.03 (Excl. VAT)
- Description
- Specifications
- Downloads
-
Planet RS232/RS422/RS485 Serial Device Server | ICS-110
Cost-effective Solution for RS232/422/485 Serial-to-Ethernet Application
PLANET ICS-110 Serial Device Server is specially designed to convert RS232, RS422 or RS485 serial communication to Fast Ethernet networking to extend the network distance efficiently and inexpensively.
There is one 10/100BASE-TX RJ45 port in the ICS-110 and its operating temperature ranges from -10 to 60 degrees C for your network needs. The ICS-110 is a time-saving and cost-effective solution for users and system integrators to quickly transform their serial devices into the Ethernet network with no need of replacing the existing serial devices and software system.
Remote Management
As the ICS-110 provides an easy serial-to-Ethernet connectivity and connection to a TCP/IP network, the remote network system can thus be managed efficiently via its Web, telnet and VCOM management interfaces. It supports both application and serial operation modes for alarm or IP address connection, which saves the network administrator’s time in detecting and locating network problems without visual inspection of the cabling and devices. Multiple connection options are available for large networking environment as well.
Easy Chassis Installation
The ICS-110 can be used as a stand-alone unit or a slide-in module to PLANET Media Converter Chassis (MC-700 and MC-1500 chassis). The media chassis can assist in providing DC power to the ICS-110 and can be DIN-rail or wall mounted for efficient use of cabinet space, without the need of replacing the existing serial equipment and software system.
Access Control System – Traditional System Application
Most of the enterprises and government use access control plate and Mifare or RFID to authorize entrance identity. Traditionally, the access control machines use RS232 or RS485 serial interface with their cables connecting to login server. By applying the ICS-110 Serial Device Server, the access control machine is able to extend the network over longer distances via Ethernet interfaces. In addition, the ICS-110 can be linked to an xDSL router to get the internet access capability so that the access control can be set and monitored over the internet.
Process Control
To monitor, configure and manage the robotic conveyer including other production machines, PLC (programmable logical control) is required to drive the above manufacturing process. The ICS-110 can be set to the TCP server mode and connected to the PLC. Thus, the administrator can configure and set command settings through Fast Ethernet intranet to remotely control the PLC, without having to stand by the I/O machine.
RTU Data Collect – UDP Mode
Connect with RTU (remote terminal unit) to collect and monitor the data of waves, signal and power utilization. The ICS-110 can be used to set up UDP mode and send data over Fast Ethernet to local server or over Internet to remote server automatically.Surveillance Motion Control – Pair Connection Mode
Using pair connection mode via the fiber optic patch cord, the ICS-110 can extend the distance of the deployed devices via RS232, RS422 and RS485 interfaces, making the remote management of these devices from the monitoring center easier and efficient.Key Features
Serial Interface
One DB9 interface supports RS232, 2-wire RS485, 4-wire RS485 and RS422 operation
Asynchronous serial data rates up to 921600bps
Data mode includes VCOM, RFC2217, TCP Server, TCP Client, UDP, Remote Pair, Modbus converter server / client and Serial Telnet modes
Ethernet Interface
1-port 10/100BASE-TX RJ45 interface with auto MDI/MDI-X function
Management
IPv4 and IPv6 dual stack management
Remote Management Interfaces
IP-based Web management
Telnet console management
Windows-based VCOM utility supports searching, monitoring and configuration setting
IP NTP (Network Time Protocol)
Standard TCP/IP interface and versatile operation modes
Software Protocol supports ICMP, TCP/IP, UDP, HTTP server, DHCP client, Telnet server/client
Serial Operation mode selected via management interface
Pair Connection mode for connecting two serial devices over a network
Allows a maximum of 4 hosts to be accessed as TCP client mode
Firmware upgrade via HTTP protocol
Accessible IP security control to prevent illegal users
Event notification
Remote syslog server
SNMP trap
DHCP client for IP address assignment
PLANET Smart Discovery utility automatically finds the client devices on the netwCase and Installation
Compact size for easy Installation
Standalone -- Wall mountable or DIN-rail mounting (optional accessory)
Co-works with PLANET MC family Media Chassis (MC-700/1500)
External power adaptor 5V DC, 2A max.
Supports 6000 VDC Ethernet ESD protection
10 to 60 degrees C operating temperature
Supports extensive LED indicators for network diagnosis
Reset button for resetting to factory default -
Category Specification Serial Interface Serial Port 1 x DB9 male Standards RS232 / RS422 / RS485 (2-wire & 4-wire) Baud Rate 50bps to 921Kbps Data Bits 5, 6, 7, 8 Stop Bit 1, 1.5, 2 Parity Type Odd, Even, None, Space, Mark Flow Control RTS/CTS, DTR/DSR (RS232 only), XON/XOFF Signals (RS232) TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND Signals (RS422/485) Tx±, Rx±, Data A/B, GND Pin Assignment Pin 1–5 RS232: DCD, RxD, TxD, DTR, GND RS422/485: TxD+/TxD−, RxD+/RxD−, Data A/B, GND Pin 6–9 RS232: DSR, RTS, CTS, — / RS422/485: — Ethernet Interface Ethernet Ports 1 x RJ45 (10/100BASE-TX) Distance Up to 100 meters ESD Protection 6KV Hardware Dimensions (W x D x H) 94 x 70.3 x 26.2 mm Weight 184g LED Indicators System: Link, TP Port: Link/Active, Serial Port: Active Power Requirements 5V DC, 2A external power adapter Power Consumption 5.5 watts (max) Material Metal Installation Standalone, wall-mount, DIN-rail (optional) Reset Button < 5 sec: Reboot, > 5 sec: Factory reset Compatible Chassis MC-700 / MC-1500 / MC-1500R Management Interfaces Web GUI, Telnet, VCOM Utility, SNMPv1/v2c, PLANET Smart Discovery, UNI-NMS IP Support IPv4 and IPv6 Operation Modes TCP Server/Client, UDP Client, Virtual COM, RFC2217, Telnet, Modbus, Pair Conn. Supported OS Windows XP, 7, 8, 10, Server 2003–2012 (some require latest WinPcap) Fault Alarm System Log, SNMP Trap Time Sync NTP Security IP Whitelist Standards Compliance Regulatory Compliance FCC Part 15 Class A, CE Protocols Supported IEEE 802.3, 802.3u, RFC 768, 791, 854, 2131, 3513, EIA/TIA RS232/422/485, etc. Environmental Operating Temp -10°C to 60°C Storage Temp -10°C to 70°C Humidity 5% to 95% (non-condensing) -
Description Downloads Datasheet Downloads
Book a Free Product Demo
Remote or on-site. No obligation.
Integrator or Installer?
Trade pricing, volume discounts, same-day collection.
Education & Public Sector Solutions
Exclusive pricing, flexible terms, and dedicated support for schools, universities, NHS, and government organisations.

Need help choosing the right product?
Speak directly with a dedicated Screen Moove expert and get the right solution, first time.
Call us on: 020 8191 9223
Email us: info@screenmoove.com
Contact us
Simply complete our contact form, and we will promptly respond to your inquiries.
If you have any questions or enquiry, please fill out the form below with all of your details and we'll get back to you shortly.